Jobs about counters allow you to automate the saving of the values of
the counters, and also adjust the accounting of mileage, engine hours
and GPRS traffic.
With this type of job, you can save the current value of the mileage
counter, reset it to zero or any other value, and save it as a parameter
in the message.
To set a new value or reset the counter, select the Set new value for mileage counter option and enter the desired value below. The counter will obtain this
value each time when the job is executed. Depending on the resource
settings, different measurement systems can be used.
Mark the Store counter value as parameter of unit data message checkbox to save the counter value as a parameter in the data message (a
sensor with this parameter should be created for the unit). It can be
used to get initial and final mileage for trips. When entering the
parameter name, it is advisable to use underscores instead of spaces. It
is recommended to store the counter values while the unit is parked,
for example, once a day at night.
The Store counter value in unit event history can be used to
store the current mileage counter value. It is especially recommended if
the counter is subject to zeroing according to the job.
This type of job is similar to the previous one, but it is applied to the engine hours sensors.
Check the Store counter value as parameter of unit data message box to save the current value of the mileage counter as a parameter in
the message, which allows to subsequently create an engine hours sensor
on its basis. When entering the parameter name, it is advisable to use
underscores instead of spaces. For more accurate calculations it is
recommended to store the counter values during the parking of the
vehicle, for example, once a day at night.
The Store counter value in unit history checkbox is responsible
for storing the value, and in its field a new value (in hours) that
will be applied to the counter after the job is completed is entered.
If you save the values of traffic, mileage, engine hours or counters in the unit history, they are recorded in the system as registered events, which allows you to display them in the Events or Chronology reports later. Saving the value of the counter as a parameter in the message occurs in the unit database in such messages as Data Message, while the hourly rate is displayed in seconds, and the mileage value, depending on the unit settings, is in meters or feet.
This job is designed to:
Indicate the status of the Store counter value in unit history option. If the option is activated, each traffic reset is registered in the system, and then you can generate a report on events or report on traffic to see traffic consumption. If the option is not activated, resets are not registered as an event.
The Reset GPRS traffic counter option is used to reset the counter to 0 when the job is performed.
Each of two options can be used both individually and together with each
other. When we check both boxes, we get a job that will reset the
counter oon the specified schedule, and the reset value will be stored
in the history.