Set the minimum and maximum permitted speed values indicated on the
scale by two markers. To place the marker to the required position, you
can either move it on the scale, or enter a value from the keyboard. The
range in which the notification triggers is highlighted in red.
Additionally, you can activate the sensor value control — in this case
the notification triggers only if both conditions are met.
When choosing this type of notification, in the next window specify the
control type: inside or outside the geofence. Also, select the geofences or groups of geofences (shown in the square brackets), for which this notification will work.
For the search convenience, you can use the dynamic filter above the
list. The geofences should be created in advance and belong to the same
resource as the notification.
Select the logical operator – the value on the basis of which the notification is activated.
For the unit inside the geofence:
For the unit outside the geofence:
In addition, you can adjust speed limitations and/or sensor value range —
then the notification triggers only if all the specified conditions are
met.
For this type of notification, no specific settings are required.
However, the equipment you use must either support the corresponding
functionality, or the compliant sensor should be set in the unit
properties.
Specify the number of the digital input and the control type: trigger in case of its activation or deactivation.
This type of notification helps to trace the parameters in the messages.
The controlled parameter must be real, that is, sent by the equipment.
Virtual parameters, such as speed, alt, sats, etc. cannot be controlled
by this type of notification.
Four control types are provided: value range, text mask, parameter availability, and parameter lack. Only real parameters, i.e. sent by
the device itself can be considered whereas virtual parameters such as
speed, altitude, sats (satellites) etc. cannot be controlled by this
type of notification.
To control Value range, specify the parameter name, define the
minimum and maximum values for it, and select whether to trigger in the
specified range or out of it. If you need to get notifications for all
parameters except 0, select a value range from 0 to 0 and select the
trigger type Out of specified range.
To control text, enter the parameter name and Text mask using wildcard symbols (? and *).
For such types of control as the Parameter availability and Parameter lack,
it is sufficient to indicate the parameter name. For the notification
to work for the parameter appearance and disappearance, on the last page
of the dialog select the Generate notification only when state changed option. For in and out parameters it is possible only to control the parameter availability/lack.
The notification can trigger when the connection is lost or restored. Select the required option in the Notification section. You can select both options at once.
Then choose the control type:
Set the loss time of data/coordinates (in minutes), after which the notification should trigger.
Using the Geofences option, you can monitor connection loss in regards to specific geofences or groups of geofences.Choose the control type: trigger inside or outside a geofence. Also,
select the geofences or groups of geofences (shown in the square
brackets), for which this notification will work. Note that the
geofences should be created in advance and belong to the same resource
as the notification.
Here you need to specify the speed and time to determine what situation
should be considered as idling (vehicle parking in supposedly working
hours). It is recommended to specify a speed greater than 0 in order to
exclude possible equipment errors. Indicate the time allowed for
parking. If this time is exceeded, a notification will trigger. Note that the maximum allowed time of idling is 98 hours and 59 minutes.
In addition, you can activate the Sensor value control — in
this case the notification will trigger only if both conditions are met.
It is convenient, for example, to control idles with the engine or
implements turned on.
Using the Geofences option, you can monitor idling in regards to specific geofences or groups of geofences.
Choose the control type: trigger inside or outside a geofence. Also,
select the geofences or groups of geofences (shown in the square
brackets), for which this notification will work. The geofences should
be created in advance and belong to the same resource as the
notification.
You can receive a notification when a SMS message arrives. To specify which SMS messages you are interested in,
enter a mask for message text. This feature can be useful, for example,
when a device sends SMS of a certain content in case of malfunction.
This notification allows you to control the approaching of the units and
their moving away from each other. Select the control type (approaching
or moving away) and the logical operator (the value, on the basis of
which the notification is activated). If OR is selected, the
notification is activated when the unit approaches or moves away from
any of the selected units. If the logical operator AND is
selected, the notification goes off when the unit simultaneously
approaches or moves away from the marked units. Specify the radius in
meters — the distance between the units whose decrease or increase will
trigger the notification. Next, select the units whose position will be
estimated in regards to the units selected for the notification. For the
search convenience, you can use the dynamic filter above the list.
In addition, you can adjust speed limitations and/or sensor value range —
then the notification will trigger only when all the conditions are
met.
The interposition of units is checked by the system using the latest messages only.
This type of notification is similar to geofence control. It allows you to control the entrance/exit or being in or out of a particular place. Enter some address parameters (e.g. city, street,
and house) and then select the most appropriate option from the found
addresses. Also specify the radius of the point. In addition, filters
for the sensor and speed can be applied.
With this type of notification, you can be warned if a unit exceeds the
limit of messages you have set. This can be either ordinary data
messages or only SMS messages. Indicate the limit of messages and set
the reset interval. For example, if you configure a notification, as
shown in the example below, the notification will trigger if unit sends 3
or more SMS messages within 1 hour.
This notification type allows you to control fuel fillings. When
creating the notification, you can specify the sensor masks that should
be used to estimate fuel fillings and their volume. Also, using the Inside geofence and Outside geofence options, you can monitor fuel fillings in regards to specific
geofences. Geofences must be created in advance and belong to the same
resource as the notification.
The notification is triggered when the minimum amount of fuel filling indicated on the Fuel consumption tab of the unit properties is reached, and also after the system
receives enough data to estimate the full amount of fuel filling (the
entire volume of data, messages from the black box, imported messages,
etc. received). In order for the notification to arrive only once (after
reaching the minimum volume of fuel filling), it is necessary to
activate the Ignore recalculated data option.
Notification is triggered for each fuel level sensor individually.
Notification of this type allows you to monitor fuel thefts. When
creating a notification, you can specify the sensor masks that should be
used to estimate fuel thefts and their volume. Also, using the Inside geofence and Outside geofence options, you can monitor fuel thefts for certain geofences. Geofences
must be created in advance and belong to the same resource as the
notification.
The notification is triggered when the minimum amount of fuel theft indicated on the Fuel consumption tab of the unit properties is reached, and also after the system
receives enough data to estimate the full amount of the fuel theft (all
data, messages from the black box, imported messages and etc. received).
In order for the notification to come only once (after reaching the
minimum amount of fuel theft), it is necessary to activate the Ignore recalculated data option.
Notification is triggered for each fuel level sensor individually.
For this type of notification, select the statuses to control: round start, round finish, arrival to check point, check
point skip, departure from check point, etc. Additionally, you can
specify a name mask for a route, schedule and/or round.
Choose control type: driver assignment or driver reset. To control both activities, two
notifications of different types will be required. Using this
notification you can control all drivers (*) or just some of them —
input driver's name (or code) mask.
Choose control type: trailer assignment or reset. Settings to adjust are the same as for previous type.
To receive notifications on passenger's activity, choose control type:
check in/out. Moreover, indicate passenger's code in the corresponding
field. To control all the passenger, leave just the asterisk sign (*) in
the field.
Indicate a timeout upon the expiry of which you'll receive an alarm
message if any passenger of a chosen resource stays in a vehicle.
Timeout is started to count upon passenger binding.
First, you choose trigger type: notify when service term approaches or
notify when service term is expired. Then indicate the interval before
or after the term for the notification to trigger. This interval can be
in days, kilometers, engine hours, or together. You can control either
all intervals existing in the 'Service Intervals' tab in unit properties or just several intervals. To specify target intervals, enter a name mask using wildcard symbols like asterisk (*) and question sign (?). Then
indicate how much mileage, or time, or how many engine hours should be
left or expired to make the notification trigger.
Notification about maintenance triggers only once — when a critical
point is met (mileage, engine hours or time) about any maintenance
interval. Then information about service work done should be delivered
through event registrar or through unit properties dialog. Only after that, the notification starts working again.
Notifications' triggering peculiarities: